This area of the Forum is Reserved for comments and discussion of specific Calculation Repository items. There is one topic for every document in the Repository. Generally authors like to receive feedback, to let them know that you value their contribution or to help them make improvements to their calculations. You might also like to make other users aware of other resources and references relating to this topic. I would encourage all users to leave some feedback when ever possible.
Go to bottom Post Reply Favoured: 0
TOPIC: Press Fits.xls
#969
JohnDoyle ()
Please support us with an XLC Pro Subscription.
User Online Now Click here to see the profile of this user
Gender: Male MoreVision Location: LEEDS, WEST YORKSHIRE, UK Birthdate: 1965-02-24
Press Fits.xls 9 Months, 2 Weeks ago Karma: 470  
Please reply to this topic to comment on or discuss Repository item:
Press Fits.xls
 
Report to moderator   Logged Logged  
 
  The administrator has disabled public write access.
#972
Re:Press Fits.xls 9 Months, 1 Week ago Karma: 1  
What is the "common radius"? I set this equal to the average of the inner radius of the outer tube and the outer radius of the inner tube but I don't think this is strictly correct. Shouldn't the spreadsheet calculate this value since it is one of the primary inputs to the results?
 
Report to moderator   Logged Logged  
  The administrator has disabled public write access.
#973
JohnDoyle ()
Please support us with an XLC Pro Subscription.
User Online Now Click here to see the profile of this user
Gender: Male MoreVision Location: LEEDS, WEST YORKSHIRE, UK Birthdate: 1965-02-24
Re:Press Fits.xls 9 Months, 1 Week ago Karma: 470  
Well it must be a value between rh and rs. In the example it is equal to rs but I also entered perhaps the more obvious choice of (rh+rs)/2 and then the lower limiting value of rh.

Using the upper limit rs gives the highest contact pressure but using the lower limit of rh reduces by just 0.9%. Since interferences are always going to be small value maybe it does not matter too much what value is used?
 
Report to moderator   Logged Logged  
 
  The administrator has disabled public write access.