RETAINING WALL DESIGN

(4/52)

Description

Cantilever Retaining Wall Design (Stability and ACI 318 Reinforcement)

Analyses a reinforced concrete cantilever retaining wall with a shear key: static and seismic earth pressures, stability against sliding, overturning, bearing pressure and stem displacement, and flexural reinforcement in five sections. A report sheet sets out the results with sketches.

Method

  • Active pressure by a Coulomb-type coefficient including wall friction, backfill slope and back-face angle, reduced for cohesion; passive pressure by the Rankine coefficient
  • Seismic coefficients Kh = 0.2(I + 1)A0 and Kv = 2Kh/3, with seismic active and passive coefficients and the extra thrusts from soil and surcharge
  • Stability: sliding (factor of safety 1.5), overturning (1.55), base pressure within the allowable soil pressure and no tension, and stem deflection within height/300
  • Reinforcement: factored moment (single load factor 1.9) at each section, rectangular stress block with φ = 0.9, and the steel ratio kept between minimum and maximum limits

Inputs

Wall dimensions, soil properties and allowable bearing pressure, backfill slope, materials, surcharge, a vertical point load and seismic parameters. SI or US units.

Outputs

Earth pressures, wall weights, the four stability checks with pass/fail, and required steel areas.

The stored example, a wall retaining 5.35 m of soil (φ = 30°, c = 8 kN/m², γ = 18 kN/m³) on a 3.65 m base with 20 kN/m² surcharge and A0 = 0.4, gives sliding and overturning ratios of 2.46 and 3.07, base pressures of 117.8 and 99.0 kN/m² (allowable 150), and 1,266 mm²/m of steel at the base of the stem.

Please note

  • The maximum steel ratio uses a concrete strain of 0.03 instead of 0.003, so it is about 2.5 times too high and would not flag an over-reinforced section.
  • The minimum steel ratio (340/fy, 0.08% in the example) is below the ACI 318 minimum for slabs and footings (0.18%); check minimum steel by hand.
  • The full passive resistance in front of the wall is counted in the sliding and overturning checks.
  • One reinforcement ratio cell on the report sheet shows #REF!. Sheets are protected. No macros.

Calculation reference: ACI 318.

Free starter: Earth Pressure on a Retaining Wall (Rankine) – a one-page, first-principles version of this calculation, free to download.

Calculation Preview

Turan Babacan (babacan)
24 May 2012
File Size 267.24 Kb
Downloads: 1183
File Version: 1.1
File Author: Turan BABACAN
File Rating (4/52)

 
Full download access to any calculation is available to users with a paid or awarded subscription (XLC Pro).
Subscriptions are free to contributors to the site, alternatively they can be purchased.
Click here for information on subscriptions.
Comments: 8
Hello Turan,
Thank you for your retaining wall calculation. We recomputed Ka, the active thrust (41.77), the passive thrust (214.2) and the base pressures (117.8 and 99.0), and all agree with the sheet.
While rewriting the description we found one clear error. On the data sheet, cell EV10 calculates the maximum steel ratio with a concrete strain of 0.03 instead of 0.003. That gives ρmax = 0.0268 in the example, against a balanced ratio of about 0.0169 (0.0108 for a tension-controlled section), so an over-reinforced section would not be flagged. Cell D359 on the report sheet also shows #REF!.
Two further points you may want to consider: the minimum steel ratio in EV8 (340/fy, 0.08% in the example) is below the ACI 318 minimum for slabs and footings of 0.18%, and the sliding and overturning checks count the full passive resistance in front of the wall, which many designers reduce or ignore.
We have mentioned these points in the file's description so users are aware. If you upload a corrected version, we will review it and publish it as the next version.
ExcelCalcs Review Team
thugyee 6 years ago
.... aaah
babacan 11 years ago
delta = angle of backfill (0 degrees for horizontal backfill)
hades3 13 years ago
Excellent work!
johndoyle-admin 14 years ago
I think it is written in Excel 2007. It may look a little different because Turan has hidden row and column headings. He also uses hyperlinks to create his innovative menu systems. All very clever.
babacan 14 years ago
VERSION 1.1 EXTRAS
+ RESULTS
+ REPORTS
+ UNITS PROBLEM CORRECTED
tim61634 14 years ago
I am having trouble with this spreadsheet when I work in US units. Has anyone else had similar problems? Please advise.
johndoyle-admin 16 years ago
Another fantastic spreadsheet Turan. You are a spreadsheet King! Thank you very much.