wind pressure ASCE 7-05
Description
Velocity Pressure qz at a Given Height to ASCE 7-05
Calculates the wind velocity pressure qz at a chosen height above ground by the analytical procedure (Method 2) of ASCE 7-05, in either US customary or SI units. Parameters are chosen from drop-down lists.
Method
- Kz = 2.01(z/zg)2/α with α and zg for exposure B, C or D (Table 6-2)
- Optional topographic factor Kzt = (1 + K1K2K3)² for ridges, escarpments and hills (Figure 6-4)
- Directionality factor Kd (Table 6-4) and importance factor I (Table 6-1, with the hurricane-region values)
- qz = 0.00256KzKztKdV²I psf, or 0.613KzKztKdV²I N/m²
Inputs
- Unit system, exposure category and height z
- Whether topography applies, with hill shape, H and Lh
- Structure type (for Kd), basic wind speed V, occupancy category and region
Outputs
Kz, Kzt, Kd, I and the velocity pressure qz.
The stored example, a building at z = 160 ft in exposure B with V = 120 mph, category II and no topographic effect, gives Kz = 1.130 and qz = 35.4 psf.
Please note
- Below the minimum height the sheet holds z at 4.6 in both unit systems. In SI this is the code’s 4.6 m, but in US units it should be 15 ft, so for z under 15 ft Kz and qz are underestimated (for example Kz = 0.51 at 10 ft in exposure B instead of 0.575).
- The topographic factor has no input for the distance x from the crest, and the K2 formula picks up the hill-shape selector instead; check Kzt by hand where topography applies.
- Gives velocity pressure only, not design pressures. ASCE 7-05 has been superseded. No macros.
Calculation reference: ASCE 7-05, Minimum Design Loads for Buildings and Other Structures; checked by the author against the examples in Mehta and Delahay’s guide to the wind load provisions of ASCE 7-02.
Calculation Preview
Full download access to any calculation is available to users with a paid or awarded subscription (XLC Pro).
Subscriptions are free to contributors to the site, alternatively they can be purchased.
Click here for information on subscriptions.
Comments: 2
×
Thank you for your ASCE 7-05 wind pressure calculation. We checked the stored example independently and got the same Kz (1.130) and qz (35.42 psf) at 160 ft in exposure B.
While rewriting the description we found two errors. Below the minimum height, C25 holds z at 4.6 in both unit systems. That is the code's 4.6 m limit, but in US units it should be 15 ft, so for z under 15 ft Kz and qz are underestimated: at 10 ft in exposure B the sheet gives Kz = 0.512 instead of 0.575, about 11% low.
Also, the topographic factor K2 in C35 uses B41, the hill-shape selector (1 to 3), in place of the distance x from the crest, and there is no input for x. This only matters when Kzt is switched on, which it is not in the stored example.
We have mentioned these points in the file's description so users are aware. If you upload a corrected version, we will review it and publish it as the next version.
ExcelCalcs Review Team