Dayton-Shear-Reinforcement-System-For-Square-Columns.xls

Rating:
3

Description


Calculates Shear reinforcement for Slabs per ACI 421.1R-7. This version is for square, and rectangular columns. It's intended to let the designer quickly try out various shear stud options for punching shear reinforcement at the column-slab junction.

Calculation Reference
ACI

Submitted On:
30 Jul 2009
File Size:
502.50 Kb
Downloads:
210
File Version:
1.0
File Author:
Andy Magee
Rating:
3

 
This download is for Registered Users Only.
Perhaps you need to login or register.
Comments: 1
MajorMagee 11 years ago
Updated to include ICC recognition per ESR-2696. Also the calculations now use a more precise burn-off length, and reflect a change in the plate thickness used with the 3/8" diameter studs.